INSTALLATION
Continuous Flow | Metered
Shot | Manually Activated
1. Continuous Flow Installation
Quick Start on demand 1.5 amp continuous flow valves should be
mounted as close to the injection site as possible. A maximum of
48 inches is suggested for peak product performance.
Do not install / mount ether systems directly on the engine, inside
the operators cab, adjacent to, or near the exhaust manifold. The
ether cylinder has a safety system that will vent the ether content
when the pressure inside the cylinder reaches 360/460 PSI.
A venting adapter and tube will direct the vented contents down
and away from the engine compartment (QSP part number QS-1313) is
available for added safety.
Suitable mounting configurations include the engine firewall,
vehicle frame and radiator frame. An optional mounting plate that
will mount the ether assembly in one piece including the cylinder
clamp is available (QSP part number QS-1189). All valves should
be mounted in the vertical position and not exceed 20 degrees in
vertical tilt in any axis.
Quick Start Products, on demand 12 and 24V, with 1.5 amp maximum
draw, continuous ether injection systems are designed to connect
directly to a dedicated port on the vehicles ECM module without
the need for a relay. Please refer to the connection instructions
as specified with the OEM application engineering specifications.
2. Metered Shot Installation
Attach the nut and ferrule assembly onto the 1/8 inch NPT fitting
located on the valve. Insert one end of the nylon/copper ether tube
into the nut and ferrule assemble making certain that the tubing
is firmly seated into the nut and ferrule assembly. Finger tighten
the nut and them continue to tighten with a wrench 1 to 1 ½ turns
beyond finger tight.
Attach the atomizer to the tube using the same process as stated
above. Please note that at this point the atomizer has not been
assembled into the manifold.
Connect the electrical wires using a switch as required for proper
operation; This system is not polarity sensitive. Activate the system
for about 34 seconds “on” followed by 3 seconds “off” without
the ether bottle attached. Look for crisp shaft movement up and
down. This will determine if the system is electrically connected
properly. The shaft should extend when electrically activated and
returns to its lower position when turned “off”.
3. Manual Activated Installation
a. The valve may be hand actuated
by operating the valve lever.
b. Drill a 3/8” hole in Dashboard
and/or fire-wall.
c. Remove nut
from control cable.
d. Insert control cable through
3/8” hole and then through control cable nut. Tighten to
hold cable securely to dashboard. Extend free end of
cable through cable clamp on valve. (Kinks, looseness
or tight bends should be eliminated by cutting off excess).
Cable casing should extend approximately ½” through
the cable clamp. Tighten cable clamp securely.
e. Insert cable
stop through hole in valve lever from the back side.
Then run actuator wire through hole in cable stop. Insert
cable screw in cable stop. Note: Before tightening cable screw
make sure to leave 1/8” space between
cable “T” handle and dashboard. Tighten cable screw.
CONNECTING THE SYSTEM
1. Mount the valve assembly as previously described.
2. Attach the correct precision fitting QSP P/N LP-5161-X, X =
the described orifice size per customer requirements) into the exhaust
port side of the valve body. Wrench torque 1 1/2 to 2 turns from
finger tight.
3. Slide the supplied nut and ferrule (LP-5146) onto the nylon
tube (LP-3239).
4. Insert nylon tube into the precision flow control fitting until
it bottoms out on the counter bored hole in the end of the
fitting.
5. Hand tighten the nut and ferrule, and then continue to wrench
tighten one (1) to one and one half (1 1/2) turns for proper
torque of the nut and ferrule assembly.
6. Repeat this process for the atomizer on the opposite end of the
nylon tubing.
7. Before attaching the Quick Start Ether Cylinder, verify that
the supplied QS-1182 gasket is in place.
8. Attach the Quick Start Ether Cylinder into the ether cylinder
port on the valve. Hand tighten only.
The system is now ready to test....
Actuate the system to insure proper operation. Check for leaks
at the cylinder connection, precision flow control fitting, both
nut and ferrules and the atomizer. A fine mist of ether should be
spraying from the orifice of the atomizer.
FINAL SYSTEM ASSEMBLY
Disconnect the nut and ferrule from the atomizer and attach the
atomizer into the proper port located on the vehicles air intake
system. The atomizer orifice is indicated on the atomizer. The atomizer
spray should be directed into the incoming air stream, avoiding
the intake manifold wall. After determining orientation, Torque
into place with 1 1/2 to 2 turns from finger tight. Reattach the
nylon tubing.
TROUBLE SHOOTING THE SYSTEM
(IF REQUIRED)
1. Check the cylinder content. An empty cylinder weight is 17
ounces. A full cylinder will weigh approximately 37 ounces. It is
our recommendation that a cylinder with 20% of its contents or less
be replaced. It is not recommended that you
try to test for pressure.
2. Before replacing the cylinder you must verify the QS-1182 gasket
is in place. DO NOT activate the system without
the gasket in place.
3. Check the cylinder for a hand tight connection.
4. If you still have a problem getting ether, disconnect the tubing
from the precision flow control fitting, activate the valve and
a fine flow of ether should be coming from the fitting. If not,
remove the control fitting and with a clean air supply, blow out
the fitting in the opposite direction of the ether flow. If you
cannot clear the blockage, replace the flow control fitting with
a new one.
5. Repeat this process at each connection point all the way through
the system, including the atomizer.
PREVENTATIVE MAINTENANCE
1. Periodically apply a drop or two of light weight silicone oil
and let it run down the actuating shaft and into the valve.
2. When the cylinder is not attached to the valve, make sure
that a dust cap is in place to prevent dirt and other types of
debris from entering the system.
If any questions arise, please call your service representative
at Quick Start @ 815-562-5414. Fax 815-562-5217, or Email us
at QuickStart-Ether.com.
|